Operation
52 / 127
Operation
7.6.1 Control portable pump in critical operating conditions
NOTICE
Unplanned event
The portable pump can be controlled at all times, even in critical operating
states (e.g. burst hose). The approach depends on the situation and is the
operating personnel's responsibility.
Variant 1:
►Actuate Idling speed function switch.
The engine speed is then automatically reduced to approx. 1700
min
-1
.
► Close pressure outlets.
Refer to chapter "Open/close discharge pipes".
Engine cooling is maintained due to the water/air cooler.
Variant 2:
►Actuate Stop propulsion engine function switch.
The portable pump is stopped immediately.
Engine cooling is interrupted.
7.6.2 Start portable pump
► Position the portable pump.
Refer to chapter "Position the portable pump".
The portable pump may only be operated with engine cover closed.
Switch on control unit
► Briefly actuate Start propulsion engine function switch.
The control unit is activated.
Screen of the control unit is illuminated.
Working light is activated.
Switch on ignition
► Briefly actuate Start propulsion engine function switch.
The ignition is switched on.
Start propulsion engine
Start propulsion engine with ignition switched on:
► Briefly actuate Start propulsion engine function switch.
The propulsion engine is started.