EasyManua.ls Logo

Rosenbauer FOX 4 - Training Mode;Competition Mode - Variant 1

Rosenbauer FOX 4
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
70 / 127
Options
With propulsion engine running:
Press the Quickstartfunction switch.
Priming pump is activated.
Once the priming process is finished the pump pressure governor is
activated.
The pump pressure governor is set to 4 bar (58 psi).
7.8.3 Training mode/competition mode - Variant 1
With the Training mode and competition modefunction several operat-
ing steps are carried out with one push of a button.
The control unit of the portable pump must be activated.
Training mode
Briefly actuate the Start propulsion engine function switch to activate
the control unit.
Control unit is activated.
Press the Training mode function switch.
Training mode is preselected.
The status LED flashes red.
►Actuate the Stop propulsion engine function switch to deactivate the
control unit.
Control unit is deactivated.
Display remains activated.
Status LED illuminates red.
►Actuate Start propulsion engine function switch.
The training mode is activated.
The following operating steps are carried out automatically.
The propulsion engine is started.
Priming pump is activated.
If priming procedure is completed the speed is increased.
Adjust the output pump pressure via the Governor function switch.
Refer to chapter "Adjust water pump pressure".
Or
Adjust the output pump pressure via the automatic pump pressure
governor.
Refer to chapter "Pump pressure regulator".
Competition mode
Briefly actuate the Start propulsion engine function switch to activate
the control unit.
Control unit is activated.

Table of Contents