EasyManua.ls Logo

Rosenbauer FOX 4 - Stop Propulsion Engine

Rosenbauer FOX 4
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
61 / 127
Operation
7.6.9 Stop propulsion engine
At high ambient temperatures (> 35°C) and an engine temperature of
above 95°C allow the propulsion engine too cool down before switching it
off in operation.
Operate the portable pump at approx. 2000-2500 min-
1
in suction state for
approx. 3-5 minutes, to regulate the engine temperature at approx. 85°C.
Adjust the propulsion engine to idling speed.
Refer to chapter "Adjust water pump pressure".
Observe engine temperature.
►Actuate Stop propulsion engine function switch.
Propulsion engine is stopped.
The screen remains active for about 2 minutes.
After approx. 10 minutes the whole control unit is deactivated.
Stop water supply.
Close the supply line.
or
Close the hydrant valve.
Disconnect suction and pressure hoses.
Reduce pressure in the risers.
First disconnect the suction hoses, then release the pressure from
the risers.
Open pressure outlets.
Pull out the spindle limitation for screw down valve (pressure relief
device).
Open pressure outlets up to the stopper.
Pressure is released via the pump and the water external drafting
connection.
Flush and drain the entire pump unit.
Refer to chapter "Flush".
Prepare the portable pump for its next deployment.
The maximum pressure for suction hoses is 3 bar.