Operation
77 / 127
Options
Close pressure outlets.
Refer to chapter "Open/close discharge pipes".
Stop propulsion engine.
Refer to chapter "Stop propulsion engine".
Operation with the external foam compound container has finished.
Flush integrated around-the-pump foam proportioning system
The foam induction valve and regulating ball valve must be closed.
Connect suction and pressure hoses to the portable pump.
Operate portable pump as described in the corresponding chapters.
"External drafting/priming".
Connect foam compound suction hose to the foam compound external
drafting connector and put the open end into a container with clean wa-
ter.
Increase pump pressure.
Refer to chapter "Adjust water pump pressure".
Fully open foam induction valve and regulating ball valve.
Open pressure outlets.
Refer to chapter "Open/close discharge pipes".
Flush until clean water comes out of all pressure outlets.
►Close foam induction valve and regulating ball valve.
Close pressure outlets.
Refer to chapter "Open/close discharge pipes".
Stop propulsion engine.
Refer to chapter "Stop propulsion engine".
The flushing procedure is completed.