Controller Functionality
42 AYC-E/Q/T60 Family Installation and Programming Manual
6.10 Programming the AYC-E/Q/T60
Programming the AYC-E/Q/T60 is performed solely via the unit's
keypad driven Programming Menu System. To reach the Programming
Menu System, the AYC-E/Q/T60 must first be placed into
Programming mode. See Section 6.10.1 for more information. During
the AYC-E/Q/T60's manufacturing process, certain codes and settings
are pre-programmed. These settings are the called the default factory
settings. Table 4 shows the names of all the AYC-E/Q/T60 menus. It
also shows of all the AYC-E/Q/T60s default factory codes and
settings.
Table 4: Controller Programming Menu
Menu
No.
Menu Description Default
4
digits
5
digits
6 digits 4–8 digits
1 Changing Lock Strike Code 2580 25802
258025 25802580
2 Changing Auxiliary Code 0852 08520
085208 08520852
3 Changing Program Code 1234 12341
123412 12341234
4 Changing Normal/Secure Code 3838 38383
383838 38383838
5 Changing Normal/Bypass Code N/A
6 Changing Door Release Time 0004
Defining auxiliary inputs/outputs 2004
Set Lockout 4000
Backlight Behavior 5100
Rosslare proximity/HID Prox
format
6300
7 Enrolling PIN Code
8 Deleting PIN Code
9 Code assignment with
strike/auxiliary
0 Return to factory defaults/Change
PIN code Length

Table of Contents