Controller Functionality
48 AYC-E/Q/T60 Family Installation and Programming Manual
2. Construct a code using the
following instructions:
First Digit
For Fail Secure Operation,
the first digit should be 0.
For Fail Safe Operation the
first digit should be 1.
Second Digit
Siren Time in minutes (1-9,
0-disabled)
Third and Fourth Digits
Enter the number of seconds
(from 1 to 99) that you want
the Lock Strike to be
released.
For example, 0312 means a Fail Secure Operation consisting of a
3-minute siren and a 12-second Lock Strike release time.
You hear three beeps.
The system returns to Normal
mode.
The default value is 0004, which corresponds to Fail Secure
operation, no siren, and 4-seconds Lock Strike release time.
6.10.9 Defining the Auxiliary Input and Output
The default auxiliary setting is 2004.
To define the auxiliary input and output:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program