Effectivity: 912 Series
Edition 1 / Rev. 0
d04059
page 115
May 01/2007
BRP-Rotax
INSTALLATION MANUAL
Fig. 75
09169
1
2
1
Fig. 74
00545
1
17.3.6) Starter relay
See Fig. 75.
- nominal voltage: 12 V
- control voltage: min. 6 V
max. 18 V
- switching current: max. 75 A (permanent)
max. 300 A (for 1 sec.)
- ambient temperature range:
min. – 40 °C (-40 °F)
max. +100 °C (214 °F)
- weight: see section 8.
- current connections (1):
M6 screw (tightening torque 4 Nm (35 in.lb)) suitable for ring
terminals to DIN 46225
- control wiring (2):
plug connector 6,3x0,8 suitable for spade connector to DIN 46247
((MIL-T-7928) (PIDG) or equivalent)
- grounding: via housing
■ CAUTION: Activation of start relay limited to short duration. Over
a period of 4 min. operation, the duty cycle is 25%.