Error Code
LCD Display
Message
Phenomenon and Possible Cause
Phenomenon and
Possible Cause
49 Reserved(bit 52) M
50 Lost Com. M<->S S
Communication between Master
and Slave Micro-controllers fails.
Please contact local agent or SAJ
Service line.
51 L1 Volt Consis Err S
The redundant measurement HW circuit
of the Grid voltage has problems.
If the error is still active, please
contact the local agent or SAJ
Service line.
52 L2 Volt Consis Err S
53 L3 Volt Consis Err S
54 L1 Freq Consis Err S
The redundant measurement HW circuit
of the Grid frequency has problems.
If the error is still active, please
contact the local agent or SAJ
Service line.
55 L2 Freq Consis Err S
56 L3 Freq Consis Err S
57 GFCI Consis Err S
The r e dun dan t m ea s ure men t H W
circuit of the GFCI has problems.
If the e rro r is stil l active,
p l e a s e co n t a c t t h e l o c a l
agent or SAJ Service line.
58 L1 DCI Consis Err S
The r e dun dan t m ea s ure men t H W
circu it o f the D CI h as p ro ble ms .
If the e rro r is stil l active,
p l e a s e co n t a c t t h e l o c a l
agent or SAJ Service line.
59 L2 DCI Consis Err S
60 L3 DCI Consis Err S
61 L1 Voltage High S
1 ) T h e l o c a l G r i d v o l t a g e i s
b e y o n d t h e p e r m i t t e d r a n g e .
2 ) T h e c o n n e c t i o n b e t w e e n G r i d
a n d i n v e r t e r h a s p r o b l e m s .
Check the Grid Compliance
of the inverter ( Ge rm an y,
Italy, A ustr alia , Denm ark ,
B e l g i u m , N e t h e r l a n d s ,
e t c ) a n d G r i d v o l t a g e .
I f ev e r y t h i n g i s c o r r e c t ,
you ne ed t o co ntact loc al
agent or SAJ Service line.
62 L1 Voltage Low S
63 L2 Voltage High S
64 L2 Voltage Low S
65 L3 Voltage High S
66 L3 Voltage Low S
67 L1 Freq High S
1 ) T h e l o c a l G r i d F r e q u e n c y i s
b e y o n d t h e p e r m i t t e d r a n g e .
2 ) T h e c o n n e c t i o n b e t w e e n G r i d
a n d i n v e r t e r h a s p r o b l e m s .
Check the Grid Compliance
of the inverter ( Ge rm an y,
Italy, A ustr alia , Denm ark ,
B e l g i u m , N e t h e r l a n d s ,
etc ) a n d G rid F req u enc y.
I f ev e r y t h i n g i s c o r r e c t ,
you ne ed t o co ntact loc al
agent or SAJ Service line.
68 L1 Freq Low S
69 L2 Freq High S
70 L2 Freq Low S
71 L3 Freq High S
72 L3 Freq Low S

Questions and Answers: