142 Program Mode Programming ER-650/650R
System Option Programming
1. At the PGM control lock position menu, press 3 for SYSTEM OPTION
Programming. The SYSTEM OPTION pg 1 screen displays:
2. Refer to "System Options - Reference Information" on page 146 to make program
entries or changes, press the ENTER key to finalize.
SYSTEM OPTION pg 1
BEEPER ACTIVE Y
REAL CLERK KEY N
CLERK ENTRY 0
0:PUSH 1:CODE
CLERK ASSIGNED WHEN
CLERK KEY IS
PUSHED (1-10) 1
SYSTEM OPTION pg 2
CLERK IS Y:POP-UP N
N:STAY-DOWN
DRAWER NEEDS TO BE
SHUT TO OPERATE Y
ACTIVATE OPEN
DRAWER ALARM N
Press
PAGE DOWN
to view the 2
nd
System Option
screen.
Press
ENTER
after making a
change, or press
ENTER
to
advance the
arrow to the
next option
without making
a change.
Press
PAGE UP
to return to the
p
revious screen.
NOTE
:
Be sure to press
ENTER
after
changing a
selection. If you
do not press
ENTER
, the
change will not
be accepted.
Press
YES/NO
to toggle from
'Y' to 'N' for yes
or no decisions.
SYSTEM OPTION pg 3
SECONDS TO ALLOW
DRAWER OPEN 30
ALLOW POST TENDER N
OPEN DRAWER ON
POST TENDER Y
ALLOW MULTIPLE
RECEIPT N
SYSTEM OPTION pg 4
CASH DECLARATION REQ
BEFORE REPORTS N
MGR CONTROL TO TEND.
NEGATIVE BALANCE N
ZERO BALANCE N
RESET TRANSACTION
NO. ON Z REPORT N
Press
PAGE DOWN
to view the 4
th
System Option
screen.
Press
PAGE DOWN
to view the 3
rd
System Option
screen.