4.AlignmentandTroubleshooting
4.2.3.Imagequalityproblem
1)VerticalBlackLineandBand
Description:Straightthinblackverticallineoccursintheprintedimage.
CheckandcauseSolution
•DamageddeveloprollerintheImagingUnit.
DeformedDoctor-bladeorcleaning-blade.
•Scratchedsurfaceofthechargerollerintheimaging
unit.
Replacetheimagingunit.
Partlydepressionordeformationonthesurfaceofthe
transferroller.
Replacethetransferroller.
2)VerticalWhiteLine
Description:Whiteverticalvoidsoccursintheprintedimage.
CheckandcauseSolution
Foreignmatterstucksontothewindowofinternallensesof
LSUmirror.
CleantheLSUwindowwithrecommendedcleaner(IPA).
Cleanthewindowwithacleancottonswab.
ThelifeoftheimagingunithasbeenexpiredReplacetheimagingunit.
Someforeignsubstancesareonthewindowoftheimaging
unitframe.
Removetheforeignmatteroftheexposurewindow.
Ifthefuserisdefective,voidsoccurperiodicallyatthetop
ofablackimage.
Opentherearcover.Reinstallthefuserunit.
4-119Copyright©1995-2016SAMSUNG.Allrightsreserved.