PY Manual Copyright © 2006 SANYO DENKI AMERICA, Inc.
102
Function Switch 4 Func4
Remote Operator Mode:
2
Page:
5
Default Value:
00000001 Bit
Function:
I/O
Setting Range:
0,1
Description:
• This parameter allows you to set the CN1-39 and CN1-40 pins to the desired terminals.
OFF at St at us Out put
CN 1-4 0 Pin Out put Logic Select
On at Status Out put0
0
0
1
INP: Positioning Complete
CMD: Command Accept Permit
SPE: Speed M atching
0
1
1
bit 0
0
LTG: Low Speed
HTG: Hig h Sp eed
1
bit 3
CMD: Command Accept Permit
INP: Positioning Complete
1
0
1
bit 4
0
CN 1-3 9 Pin Out put Terminal
ILM : Current Limit St at us
LTG: Low Speed
HTG: Hig h Sp eed
SPE: Speed M atching
CN 1-4 0 Pin Out put Terminal
ILM : Current Limit St at us
1
1
1
0
1
CN 1-3 9 Pin Out put Logic Select
OFF at St at us Out put
0
0
On at Status Out put
bit 1
0
0
1
76 5432 10
bit 2
0
0
1
1
0
0
0
1
bit 5
00
0
0
1
0
0
0
1
•
The standard value is set at 00000100 in the position control mode.