Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
6 205_R
26
0-31
7 605_G
26
0-31
8 A05_B
26
0-31
9 300_R
130
0-255
10 700_G
130
0-255
11 B00_B
130
0-255
Group
106
Panel Service(62334)
0 VMID
178
0-255
1 VREF_R
242
0-255
2 VREF_G
242
0-255
3 VREF_B
242
0-255
Group
200
Option
0
Logo Prohibition (Forced No
Brand)
Logo Prohibition (0: Menu, 1: Forced,
2: China, 3-9: not used)
0 0 - 2 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 1 0: 19200bps, 1: 9600bps,
4 CABLE SW Long Cable 0 0 - 1 0: Disable, 1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial Command Enable)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
8 PJ - NET Hang Up Check 0 0 - 1 0:Enable, 1:Disable
50 Lamp Replacement Display Lamp Warning Display On / Off 1 0 - 1 1: On, 0: Off
51 Filter Warning Display Filter Warning Display On / Off 1 0 - 1 1: On, 0: Off
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
53 Filter Counter Reset Times Reset Times of Filter 0 0 - 255 Read only
54
Factory Default Execute
Times
Reset times of Fanctory Default 0 0 - 255 Read only
55 Motor Disable Motors Disable - 0 - 1 0: On, 1: Off
56 Menu Position Move menu (X axis) 0 0 - 1024
57 Menu Position Move menu (Y axis) 0 0 - 1024
58 Lamp Go Out 0 0 - 1
63 Souce Search Enable Source Search Enable 1 0 -1 0: Disable 1:Enable
70 Analog ADC Device Select 0: ISL51002, 1:PW392 AFE 0 0 - 1
71
Component ADC Device
Select
0: ISL51002, 1:PW392 AFE 1 0 - 1
80 Determination Setting 0: English 1: Japanese 0 0 - 1
100 Disable Auto Picture Control
0: Normal operation
1:Auto Picture Control
- 0 - 1
Group
201
Option (signal)
0 FrameLock Option 1 0 - 1
0: Allway_ OFF
1: Operation Normal ON/OFF
acording to the input frequeney
Enable only for PC signal.
1 Dither Enable 0:Disable 1:Enable 1 0 - 1
3 Field Sense Invert Enable 0: Disable 1: Enable 0 0 - 1
Group
204
Simulation mode
0 PW392C Enable
0:Shimulation mode OFF
1:Shimulation mode ON
0 0 -1
1 PW610 Enable
0:Shimulation mode OFF
1:Shimulation mode ON
- 0 - 1
Group
205
Spread Spectrum
0 Enable 0: Disable 1: Enable 1 0 -1
1 Spead factor Default: 100 100 0 - 300
2 Wave period Default: 300 80 1 - 500
Group
210
LampContorl
0 Dimmer SW 0: Auto 1: Manual 0 0 - 1
1 Manual Control
Lamp manual control
0(Dim)-15(Bright)
0 0 -15
2 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
7 0 - 255