68
Maintenance and Cleaning
Thisprojectorusesahigh-pressurelampwhichmustbehandledcarefullyandproperly.
Improperhandlingmayresultinaccidents,injury,orcreateafirehazard.
Lamplifemaydifferfromlamptolampandaccordingtotheenvironmentofuse.Thereisnoguarantee
ofthesamelifeforeachlamp.Somelampsmayfailorterminatetheirlifeinashorterperiodoftime
thanothersimilarlamps.
Iftheprojectorindicatesthatthelampshouldbereplaced,i.e.,iftheLAMPREPLACEindicatorlights
up,replacethelampwithanewoneIMMEDIATELYaftertheprojectorhascooleddown.
(FollowcarefullytheinstructionsintheLampReplacementsectionofthismanual.)Continuoususeof
thelampwiththeLAMPREPLACEindicatorlightedmayincreasetheriskoflampexplosion.
A Lampmay explode asa result ofvibration, shock ordegradation as aresult of hoursof use asits
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in
whichtheprojectorandlamparebeingused.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector’sAC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp.Additionally, check
carefullytoensurethattherearenobrokenshardsorpiecesofglassaroundtheprojectororcomingout
fromthe cooling aircirculation holes.Anybroken shardsfoundshould becleaned upcarefully.Noone
should check the inside of the projector except those who are authorized trained technicians and who
arefamiliarwithprojectorservice.Inappropriateattemptstoservicetheunitbyanyone,especiallythose
whoarenotappropriatelytrainedtodoso,mayresultinanaccidentorinjurycausedbypiecesofbroken
glass.
LAMP HANDLING PRECAUTIONS
Resetting the Lamp Counter
BesuretoresettheLampcounterafterthelampisreplaced.WhentheLampcounterisreset,theLAMP
REPLACEindicatorstopslightingandtheLampreplacementicondisappears.
Note:
Do not reset the Lamp counter without implementing
lamp replacement. Be sure to reset the Lamp counter
onlyafterreplacingthelamp.
Lamp counter Reset?
appears.
SelectYes,thenanother
confirmationboxappears.
SelectYesagaintoreset
theFiltercounter.
PresstheMENUbuttontodisplaytheOn-Screen
Menu.UsethePoint▲▼buttonstoselectSettingand
thenpressthePoint►ortheSELECTbutton.
UsethePoint▲▼buttonstoselectLamp counter
andthenpresstheSELECTbutton.UsethePoint▲▼
buttonstoselectLamp counter resetandthenpress
SELECTbutton.Lamp counter Reset? appears.
SelectYestocontinue.
1
2
Anotherconfirmationdialogboxappears,selectYesto
resettheFiltercounter.
3