EasyManua.ls Logo

Scaime eNod4-D ETHERNET - In-flight correction Settings

Scaime eNod4-D ETHERNET
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
SCAIME Manual : NU-eNod4D-ETH-E-0418_216710-E.docx
Page 1/3
Start cycle delay
0 – 6553 ms
This stabilization time precedes the tare execution.
Meas. Stab delay
This stabilization time follows the FF stop. After this delay, a new
dosing result is calculated by eNod4 –D under stability conditions.
End of cycle delay 0 – 65535 ms
This waiting time occurs after Emptying/Reloading. A dosing cycle is
considered complete after this delay.
Page 2/3
HF / CF / FF masking
time
0 – 6553 ms
During this delay, flow rate and level control are disabled to mask the
dynamic effects caused by the related feed activation.
Page 3/3
Emptying /
Reloading Holding
time
0 – 65535 ms
Defines how long the ‘emptying / Reloading’ output remains active
after the ending of Emptying (or reloading) conditions.
Calculation time for
Tare / result
0 – 6553 ms
Max. time to search stability for Tare or Result determination. In
dynamic mode, Time to calculate Tare or Result
Dynamic Zero time time for average calculation used for ‘Dynamic Zero’ command
13.2.4 In-flight correction Settings
Parameter Possible Value Description
In
-
flight correction parameters

Table of Contents

Related product manuals