80
SCAIME Manual : NU-eNod4D-ETH-E-0418_216710-E.docx
Parameter Possible Value Description
Target weight 0 – 1 000 000
Target weight represents the value to reach at the end of the dosing
process.
CF to FF Level
0 – 1 000 000
Used in sequences using at least 2 or 3 feeds.
Defines the transition threshold, relative to the target weight,
between the Coarse feed and Fine Feed phase.
FF to CF Level
Used in sequences where FF comes before a CF phase.
Defines the transition threshold, relative to the target weight,
between the Fine Feed and Coarse Feed phase.
HF to CF Level
Used in sequences using 3 feeds.
Defines the transition threshold, relative to the target weight,
between the High Feed and Coarse Feed phase.
CF only
(CF + FF) – FF
FF – CF – FF
FF – (CF + FF) – FF
HF – CF – FF
(HF + CF + FF) – (CF + FF) – FF
(HF + CF) – CF – FF