www.scheppach.com
28
|
GB
15. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault Possible cause Remedy
Engine cannot be started
Automatic oil shut-o reacts (red LED Check oil level, ll with engine oil
No diesel fuel Top up diesel fuel
Mechanical circuit breaker unlocked Slide mechanical circuit breaker to
the right
Diesel lter blocked Clean or replace diesel lter
Air lter blocked Clean or replace the air lter
Diesel fuel “congealed” due to low outdoor
temperature
Proceed as described under “Win-
ter operation” section
Fuse defective Change defective fuse
Generator has insucient or
no voltage
Controller or capacitor defective Contact the specialist dealer
Overload protection switch triggered Reduce consumption
Air lter dirty. Clean or replace lter
Battery is not charged Fuse defective Change defective fuse