Technical data
09.00 | PGN-plus | Assembly and Operating Manual | en | 389296
17
3 Technical data
Designation PGN-plus
Pressure medium Compressed air,
compressed air quality
according to
ISO 8573-1: 7:4:4
Nominal operating pressure [bar] 6
Minimum pressure [bar]
without maintenance of gripping force
with maintenance of gripping force
2.5
4
Max. pressure [bar]
without gripping force maintenance
with gripping force maintenance
Force intensified version (KVZ)
8
6.5
6
Pressure range for air purge [bar] 0.5 - 1
More technical data is included in the catalog data sheet.
Whichever is the latest version.
Ambient conditions and operating conditions
Designation PGN-plus
Ambient temperature [°C]
min.
max.
+5
+90 / (V/HT: +130)
Protection class IP * 40 / (SD: 64)
Noise emission [dB(A)] ≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized
solutions for special applications in dirty ambient conditions.

Table of Contents