SPN CID SID PID PPID FMI
John Deere
Volvo
Perkins
Description Comment
282 282 Overspeed output status
3 Overspeed output open/short to B+
4 Overspeed output short to ground
285 285 Coolant temperature output status
3
Coolant temperature lamp open/short to
B+
4
Coolant temperature lamp short to
ground
286 286 Oil pressure output status
3 Oil pressure output open/short to B+
4 Oil pressure output short to ground
5 Oil pressure output open circuit
323 323 Shutdown output status
3
Shutdown output open/short to B+
4 Shutdown output short to ground
5 Shutdown output open circuit
324 324 Warning output status
3 Warning output open/short to B+
4 Warning output short to ground
5 Warning output open circuit
412 Temperature sensor in the EGR valve.
0 Temperature in the EGR extremely high
3
Input voltage of the temperature sensor
high
Short to V+
4
Input voltage of the temperature sensor
low
Short to V-
15 Temperature in the EGR high
16 Temperature in the EGR moderately high
443 443 ENGINE RUN output status
3 Engine run output open/short to B+
4 Engine run output short to B-
523 Gear selection
9 Gear selection invalid
Not possible with Genset
application
608 250
Data link faulty J1587 Start/Stop
redundancy / J1939 communication
bus
608 132 Redundancy of the accelerator
608 98
Redundancy of the Stop/start
information
611 Injector wiring status
3 Injector wiring shorted to power source
4 Injector wiring shorted to ground
620 262 232 5 Volt sensor power supply
FMI not informed by
VOLVO
3 Sensor power supply open/short to B+
4 Sensor power supply short to ground
275/285