ELECTRICAL SYSTEM
14 - 11
Charging condition check
Battery charging status can be measured to check the
battery terminal voltage.
Remove the battery (refer to the section on
Removing the battery).
!
First, make sure to disconnect the negative (-)
Measure the battery terminal voltage.
!
The voltage to one decimal point is measured with a
readable digital voltmeterA.
If the reading is below the rated value, it needs to be
recharged.
Battery terminal voltage standard: 12.6V or higher
Remove the battery (refer to the Removal of
batteries section)
Recharge the battery in the following way.
!
The battery is sealed. Do not open it. Do not add water
when charging.
The charging current and time are described below.
Terminal voltage: 11.5 _ Less than 12.5 V
Standard charge: 3.2 amps x 5 _ 10 hours
(see attached table)
Quick charge: 32 A x 1.0 hours
!
If possible, do not charge quickly. If there is an inevitable
situation that requires a quick charge, pay attention to
the ambient temperature.
Test against the standard voltage later.
Terminal voltage: less than 11.5V
Charging method: 3.2 A x 20 hours