EasyManua.ls Logo

Segway SNARLER SGW570A6 2021 - Fault Diagnosis; Performance Parameters

Segway SNARLER SGW570A6 2021
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL SYSTEM
14 - 24
Performance parameters
Project Parameter
Static fl ow 207.8g/min
Dynamic fl ow 6.65mg/stroke
Jet angle 23°
Coil resistance 12Ω
Hydraulic leak 1.8mm3/min
A
B
Fault diagnosis
ECU only implements fault diagnosis for the fuel injector
drive stage. When the fuel injector drive stage is short-
circuited or overloaded to the battery voltage, short-
circuited to the ground, or open circuit, the fault fl ag is set.
At this time, close the closed-loop control of the oxygen
sensor and its self-learning pre-control. The last self-
learning data is valid. After the fault is removed, the fault
ag is reset. Common fault codes are shown in the fault
summary table
Injector failure inspection:
Check the connectors are well connected
Check whether the wiring harness and injector pins
are bent or deformed
Check whether the injector cap and the oil pipe are
reliably connected
Unplug the connector and check the coil resistance
between pins
A
and
B
Check the resistance between the pins (A on
the left) and the main relay
Check the resistance between the pins (
B
in the
left picture) and ECU pin 48 (see ECU pin defi nition)
!
When removing the fuel pipe, there is high-pressure fuel
in the fuel pipe. Pay attention to re safety and spray it
into your eyes carefully.

Table of Contents