General Features
11
811-000-000 SDS© DC-PWM Compatible Edition 25 March 2016
3 GENERAL FEATURES
3.1 TECHNICAL INFORMATION
3.2 SEMATIC DRIVE SYSTEM© DOOR CONTROLLER (DC-PWM)
1. Power ON button
2. Power OFF button
3. Display
4. Manual mode buttons
5. RJ45 Connection port (Handset)
6. 6 poles motor and auxiliary EOD battery power supply connector (cod. E066AARX-05)
7. RJ45 Connection port (Motor optical Encoder)
8. 4 poles detector / photocells connector (cod. E066AARX-06)
9. 6 poles Main Lift Controller signals connector (cod. E066AARX-03)
10. 6 poles Main Lift Controller signals connector (cod. E066AARX-04)
11. 10 poles Main Lift Controller signals connector (cod. E066AARX-07)
MAIN SUPPLY VOLTAGE 90-290 Vac (115 V-20%, 230V+26%), 50-60 Hz
TYPICAL POWER CONSUMPTION 200 VA
PEAK POWER CONSUMPTION 300 VA
MOTOR OVERLOAD PROTECTION @In <15 minutes
@2In <3 minutes
OPERATIONAL TEMPERATURE
RANGE
from -10°C to +60°C
HUMIDITY non-condensing between 20% and 80%
PROTECTION rapid cartridge fuse [5x20, 4 A]
battery fuse [5x20, 8 A]
PERFORMANCE SPEED separately adjustable for opening and closing
REVERSAL SENSITIVITY Variable, only operational on door closing cycle