ENGLISH
www.sematic.com
Changes can be made without notice
Instruction without handset
19
811-000-000 SDS© DC-PWM Compatible • Edition 25 March 2016
5.3 PROGRAMMING MODE “PROG”
• When the Door Controller is working in “programming mode” the “PROG” red led is on whereas the other two
red leds are off.
• Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode. The display on
the Door Controller will show “P” and “00” flashing alternately.
• When the Door Controller is in the programming mode, all signals coming from the main lift controller and
from the external devices (barriers, photocells,…) are ignored.
• The parameter to be modified is selected by means of the increasing and decreasing KEYs, respectively the
buttons 2 and 3; this parameter is then confirmed by pushing the key 1, ENTER.
• After confirming the parameter to be modified, the display shows the relevant numeric value.
• Modify the chosen parameter using the key 2, increase, and 3, decrease, and confirm the changes by pressing
key 1 ENTER.
• At the end of the necessary configurations, using the key 4 press to select the required operating mode
(manual “MAN” or automatic “AUTO”).