811-000-000 SDS© DC-PWM Compatible Edition 25 March 2016
5.3 PROGRAMMING MODE “PROG”
When the Door Controller is working in programming mode” the “PROG” red led is on whereas the other two
red leds are off.
Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode. The display on
the Door Controller will show “P” and “00” flashing alternately.
When the Door Controller is in the programming mode, all signals coming from the main lift controller and
from the external devices (barriers, photocells,…) are ignored.
The parameter to be modified is selected by means of the increasing and decreasing KEYs, respectively the
buttons 2 and 3; this parameter is then confirmed by pushing the key 1, ENTER.
After confirming the parameter to be modified, the display shows the relevant numeric value.
Modify the chosen parameter using the key 2, increase, and 3, decrease, and confirm the changes by pressing
key 1 ENTER.
At the end of the necessary configurations, using the key 4 press to select the required operating mode
(manual “MAN” or automatic “AUTO”).