Do you have a question about the sematic SDS and is the answer not in the manual?
Details the speed profile configuration for opening and closing cycles.
Provides key technical specifications like voltage, power, temperature, and protection.
Describes the components and connectors of the DC-PWM door controller unit.
Details the compatible connection interfaces for the Sematic Drive System.
Explains the system set-up and incoming/outgoing signals from the door controller.
Covers signal-only and complete connection methods for detectors and photocells.
Describes the operation and connection of magnetic switches for door limits.
Details the automatic mode operation, LED indicators, and key functions.
Explains the manual mode operation, ignoring external signals and manual commands.
Guides on entering and using the programming mode for parameter adjustments.
Sets the sensitivity for obstacle detection during door closure.
Allows selection between internal or external control for the reversing system.
Enables partial door re-opening upon obstacle detection by safety devices.
Checks for MLC signals during door movement for system diagnostics.
Configuration for the optional car door locking device.
Activates specific settings for glazed paneled doors, including speed restrictions.
Configures the auxiliary output relay for signaling events like Gong or space percentage.
Enables forced closing command for situations with disabling photocell circuits.
Sets the logic for protective device input (Kn) based on obstruction status.
Selects the emulation type for controller compatibility.
Details the controller's ability to diagnose, record, and signal defects.
Describes the optional handset and its ideal connection for safe operation.
Provides a comprehensive guide to navigating handset menus and submenus for settings.
Instructions for adjusting the reversing system force using the handset.
Guides on modifying speed profiles and high-speed settings using the handset.
Details accessing advanced settings like opening/closing parameters and password.
Configuration options for opening speed, acceleration, and deceleration.
Configuration options for closing speed, acceleration, and deceleration.
Procedure for changing the handset access password.
Allows resetting the speed parameters for the initial reset cycle.
Configures input/output logic levels for interface with the main lift controller.
Adjusts delays for opening/closing slow down for Digidoor emulation.
Area reserved for factory use, requiring a 5-code password.
Sets the reversing system choice (Internal or External) using the handset.
Activates the Main Lift Controller test via the handset.
Configures the activation of Main Lift Failure detection (Immediately Stop).
Configures the MLC Input Alarm setting (On/Off) via the handset.
Activates or deactivates the Limited Door Reversal function via the handset.
Enables or disables the Car Door Locking Device setting via the handset.
Activates or deactivates the Glazed Paneled Doors setting via the handset.
Sets the function for the Auxiliary Output Relay via the handset.
Configures the logic for the Protective Device input (KN) via the handset.
Selects the emulation type for controller compatibility via the handset.
Guides on accessing and navigating the Maintenance Menu using the handset.