14.2 Commands
14.2.1 SetTxCw
The command SetTxCw ( ) sets the device in TX continuous wave mode (unmodulated carrier).
This command immediately sets the device in TX CW mode. Therefore, the operating frequency and the PA configuration
commands (including the RF output power) have to be called prior to this command.
14.2.2 SetTxInfinitePreamble
The command SetTxInfinitePreamble( ) transmits an infinite preamble sequence.
This command immediately starts transmission of the infinite preamble sequence. Therefore, the operating frequency and
the PA configuration commands (including the RF output power) have to be called prior to this command.
Table 14-2: SetTxCw Command
Byte 0 1
Data from Host 0x02 0x19
Data to Host Stat1 Stat2
Table 14-3: SetTxInfinitePreamble Command
Byte 0 1
Data from Host 0x02 0x1A
Data to Host Stat1 Stat2