EasyManua.ls Logo

Semtech LR1110 - Page 122

Semtech LR1110
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LR1110
User Manual Rev.1.0
UM.LR1110.W.APP March 2020
122 of 130
Semtech
www.semtech.com
SetPaConfig 0x0215
PaSel
RegPaSupply
PaDutyCycle
PaHpSel
Configure PA settings
StopTimeoutOnPreamble 0x0217
StopOnPreamble (0 = stop on
Sync/Head, 1 = stop on Preamble)
Stop RX time-out on Syncword/Header
(default) or preamble detection
SetCad 0x0218 --- Set chip into RX CAD mode (LoRa®)
SetTxCw 0x0219 ---
Set chip into TX mode with infinite carrier
wave
SetTxInfinitePreamble 0x021A ---
Set chip into TX mode with infinite
preamble
LoRaSynchTimeout 0x021B NbSymbols
Configures LoRa® modem to issue a
time-out after exactly NbSymbols symbols
SetGfskCrcParams 0x0224 SeedValue, PolyValue Sets the parameters for the CRC polynom
SetGfskWhitParams 0x0225 SeedValue Sets the parameters for the whitening
SetRxBoosted 0x0227 BoostedGain Sets the RX to boosted mode
Table 15-3: Radio Configuration / Status Operation
Command Opcode Parameters Description

Table of Contents