15
Technical data
Technical data for field distributors
Manual – EtherCAT
®
Interfaces, Field Distributors
125
15.4.4 MF../MM../Z.8. field distributors with operating point 400V/50Hz
MF../MM..-503-00/Z.8.
MOVIMOT
®
inverter MM
03D
MM
05D
MM
07D
MM
11D
MM
15D
MM
22D
MM
30D
MM
40D
Size 1 2 2L
Connection voltages V
line
AC 3 x 380V -10% – AC 500V +10%
Line frequency f
line
50–60Hz
Max. permitted total cur-
rent X1
(X1 terminal)
I
max
32A (according to UL max. 30A)
Motor power S1 P
Mot
0.37kW
0.5HP
0.55kW
0.75HP
0.75kW
1.0HP
1.1kW
1.5HP
1.5kW
2.0HP
2.2kW
3.0HP
3.0kW
4.0HP
4.0kW
5.4HP
Nominal line current I
line
AC
1.3A
AC
1.6A
AC
1.9A
AC
2.4A
AC
3.5A
AC
5.0A
AC
6.7A
AC
7.3A
Nominal output current I
N
AC
1.6A
AC
2.0A
AC
2.5A
AC
3.2A
AC
4.0A
AC
5.5A
AC
7.3A
AC
8.7A
Output voltage V
O
0 – V
line
Max. permitted total cur-
rent X21
(X21 terminals)
32A
Max. permitted total cur-
rent X20
(X20 terminals)
12A
Maintenance switch Load disconnector
Type: ABB OT16ET3HS3ST1
Switching: black/red, triple lock
Ambient temperature -25°C–40˚C (P
N
reduction: 3% I
N
per K to max. 55°C)
Storage temperature -25°C–85°C
Degree of protection IP65 (fieldbus interface, power supply connection cover, MOVIMOT
®
in-
verter and motor connection cable attached and fastened, all plug con-
nections sealed)
Interface PROFIBUS, PROFINET IO, EtherNet/IP™, EtherCAT
®
, DeviceNet™
Permitted motor cable
length
15m (with SEW‑EURODRIVE hybrid cable, type A)
Mass Approx. 5.2kg Approx. 6.7kg
25809148/EN – 01/2019