4
Installation notes
MOVI-C® CONTROLLER power UHX85A / power eco UHX84A
Manual – MOVI-C
®
CONTROLLER
17
No. Designation Terminal Function
[3] Connector LAN 3:
Ethernet interface connection (RJ45
socket)
LAN 3 Engineering interface for the control section of
the MOVI‑C
®
CONTROLLER
Default IP address: 192.168.10.4
[3] Connector LAN 4:
Ethernet interface connection (RJ45
socket)
LAN 4 In preparation
[4] Connector USB 1, 2, 3, 4, 5, 6, 7: 7
× USB port (USB 2.0)
USB 1 – 7 Standard USB assignment (USB 2.0)
[5] Connector DVI-I:
DVI-I interface
DVI-I Monitor connection
[6] Connector X1:
Plug-in terminals
X1:' Digital ground and housing potential
X1: Electrically isolated output with internal resistor
to limit the current to about 10mA. An LED can
be connected here as a power status display.
X1: Electrically isolated input. Connection of a button
to switch the MOVI‑C
®
CONTROLLER on and
off:
Pushing the button briefly switches on the
deactivated MOVI‑C
®
CONTROLLER.
Pushing the button briefly during operation
shuts down the MOVI‑C
®
CONTROLLER.
Pushing the button for at least 5s switches
off the MOVI‑C
®
CONTROLLER.
X1:On Electrically isolated input. Connection of a button
to switch the MOVI‑C
®
CONTROLLER on.
X1:M Common ground for all electrically isolated in-
puts/outputs
X1:− Connection of DC 24V supply (−)
X1:+ Connection of DC 24V supply (+)
[7] Connector X2:
PCIe slot
X2 Option card slot for fieldbus interface UHX85A–
P/UHX84A–P or UHX85A–R/UHX84A–R
Cannot be changed later. Only available as unit
variant.