4.1.3 Voltage supply
An external DC24V power supply unit (power consumption P
max
= 100W) has to be
used for the voltage supply of the MOVI‑C
®
CONTROLLER.
Wiring diagram
24V
X1
+
-
DC 24 V supply
for control electronics
+-
14344508683
4.1.4 Connecting the MOVI-C
®
CONTROLLER to the Ethernet network
To connect the MOVI‑C
®
CONTROLLER to the Ethernet, connect one of the Ethernet
communication interfaces LAN1 or LAN3 (RJ45 plug connector) to the other network
stations using a category5, classD twisted-pair cable in accordance with IEC11801
edition2.0.
22781455/EN – 05/2016