EasyManua.ls Logo

SEW-Eurodrive MOVI-C Series - Project Planning and Startup with Windows 7 Embedded; Windows 7 Embedded Setup Basics

SEW-Eurodrive MOVI-C Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Project planning and startup with Windows
®
7 Embedded
General information
Manual – MOVI-C
®
CONTROLLER
30
5 Project planning and startup with Windows
®
7 Embedded
5.1 General information
INFORMATION
The Windows
®
7 Embedded operating system on the OMW71B/72B memory card
is only available in English.
If you want to use a OMW71B/72B remote desktop connection, you have to use a
user password.
5.2 Starting the Windows
®
operating system the first time after delivery
Initial start
of the
Windows
operating
system
after
delivery
The initial start process of the Windows
®
7 Embedded operating system includes sev-
eral setup screens that allow you to adjust the operating system to your requirements.
You will be prompted to confirm the system time and set the user name. The conven-
tional Windows
®
dialogs allow you to adapt, for example, the currency and date format
to your region.
The setup of the operating system is completed by initially starting the MOVI‑PLC
®
power apps software. The "Addresses" window opens automatically. This window lists
the preset IP addresses (LAN1 and VNET). SEW‑EURODRIVE recommends to adopt
these default values. This especially applies to the virtual network card (VNET set-
tings) as it is otherwise not possible to establish a direct connection of Windows
®
and
the control section. You find more information in chapter "Using the MOVI‑PLC
®
power
apps software".
5.3 Switch-off and reboot behavior of the MOVI‑C
®
CONTROLLER
Switch-off
and reboot
behavior of
the MOVI-
CONTROLL
ER
5.3.1 General information
If the controller is operated with the OMW71B/72B memory card and the OMH71B
Windows
®
CFast memory card, then it represents a combined device. The controller
comprises a control section as well as a Windows
®
section. In this case, the Windows
®
switch-off and reboot behavior is different to that of normal desktop PCs.
Restarting Windows
®
Windows
®
restarts. The control section keeps running normally without a restart.
Shutting down Windows
®
Windows
®
and the control section are shut down. Switch the controller's voltage
supply off and back on to start the system.
INFORMATION
SEW‑EURODRIVE recommends to properly shutdown Windows
®
7 before you
switch off the supply voltage.
In MOVI‑PLC
®
power apps, activate the "Write protection" menu to switch off the
supply voltage during normal operation of Windows
®
.
22781455/EN – 05/2016

Table of Contents

Related product manuals