4
Installation notes
MOVI-C® CONTROLLER power UHX85A – P / power eco UHX84A–P
Manual – MOVI-C
®
CONTROLLER
23
Status Possible cause Measure
Green Connection to the PROFIBUS
master is OK.
–
Red Wrong PROFIBUS DP configura-
tion.
Check the configuration settings.
Flashing red,
cyclically
• Connection to the DP master
has failed.
• Bus interruption has occurred.
• PROFIBUS DP master not in
operation.
• Check the PROFIBUS con-
nection of the device.
• Check the project planning of
the PROFIBUS DP master.
• Check all the cables in the
PROFIBUS network.
Flashing red,
acyclically
The PROFIBUS station has not
been configured.
–
Status LED "25.4" (SYS)
Signals proper operation of the PROFIBUS electronics (hardware).
Status Possible cause Measure
Green The fieldbus slave is OK. –
Orange The fieldbus slave is being ini-
tialized.
–
22781455/EN – 05/2016