AR-5726/5731 SIMULATION 6 - 34
Operation/Procedure
(Max. position setting)
1. Set the guide to the maximum position, and press the [START] key.
2. Set A4R and fit the guide, and press the [START] key.
3. Set A5R and fit the guide, and press the [START] key.
4. Set the guide to the minimum position, and press the [START] key.
5. Set the paper recognition width (+), and press the [START] key.
6. Set the paper recognition width (–),and press the [START] key.
If “FAILED” is displayed in the above procedure 1, 2, 3, or 4, repeat the
adjustment.
(Middle position L/S setting)
Operation/Procedure
1. Touch the item to be adjusted.
The item and the currently set value are highlighted.
2. Enter the RSPF original tray size adjustment value (specified on
the back of the RSPF) with the 10-key.
Operation/Procedure
With the RSPF or the OC cover open, put a white paper on the OC
glass (the RSPF glass surface is included for the RSPF standard
model), and press the [START] key.
If the adjustment is executed normally, the adjustment value is dis-
played and saved in the EEPROM. If an error occurs, “ERR” is dis-
played and the value is not saved in the EEPROM.
If the adjustment is not performed because of abnormality, “---” is dis-
played.
During execution of the adjustment, the operation cannot be inter-
rupted.
Operation/Procedure
Press [START] key.
Operation/Procedure
1. Press [START] key.
2. Enter the adjustment value with the 10-key.
Operation/Procedure
Used to enter the number of SW to be changed.
The bit to be changed is specified by 10-key. (The current value is
highlighted.)
When [START] key is pressed, the entered value is set.
Operation/procedure
Press the [START] key, and the LSU test is performed.
Used to set the LSU to ON state and check that the sync signal
(HSYNC/) is outputted or not.
After operation for 30 sec, the result is displayed. (Interruption cannot
be made for 5 sec after starting the operation.)
53
53-6
Purpose Adjustment
Function
(Purpose)
Used to adjust the detection level of the RSPF width.
The adjustment method is the 4-point system. Set the
guide to Max. (A3/WLetter) position, A4R/Letter R
position, A5R/Invoice R position, and Min. position for
adjustment.
Section RSPF
Middle position
adjustment L
YES MID-L ADJ.ON
NO MID-L ADJ.OFF
Middle position
adjustment S
YES MID-S ADJ.ON
NO MID-S ADJ.OFF
53-7
Purpose Adjustment
Function
(Purpose)
Used to enter the RSPF width detection adjustment
value.
Section RSPF
Item Content Setting range Default
1 MAX POSITION Max. width
0-999 0
2 POSITION 1 Adjustment point 1
3 POSITION 2 Adjustment point 2
4 MIN POSITION Min. width
53-8
Purpose Adjustment
Function
(Purpose)
Used to adjust the RSPF scan position of the mirror
unit automatically. For the RSPF scan position
automatic adjustment, the mirror unit is shifted to
11mm before the RSPF glass cover edge, and is
operated automatically to scan images by the unit of 1
step, detecting the position up to the glass cover
automatically.
53-9
Purpose Adjustment
Function
(Purpose)
RSPF read position adjustment
Item Setting range Default
Read position adjustment 1-99 50
53-10
Purpose Adjustment
Function
(Purpose)
RSPF exp adjustment
Item Setting range Default
1 SPF EXPOSURE
1-99 53
2 RSPF EXPOSURE
55
55-1
Purpose Setting
Function
(Purpose)
Used to set the soft switch.
Section Operation
61
61-1
Purpose Operation test/check
Function
(Purpose)
Used to check the LSU (polygon motor) operation.
Check speed can select 145mm/s or 122mm/s
individually.
Section LSU
Item Operation