AR-5726/5731 SPECIFICATIONS 2 - 4
F. Paper exit section
(1) Center tray of main unit
G. Copy functions
(1) Copy magnification ratio
(2) Density/copy image quality process
(3) Duplex
∗ When duplex printing is continued in a certain level of temperature,
the printing speed may be reduced in order to prevent an abnormal
temperature rise in the machine.
(4) Copy functions
H. Printer function
(1) Platform
(2) Support OS
I. Environmental conditions
Paper exit position/
system
Main unit top surface face-down paper
exit
Paper exit capacity 500 sheets (A4, 8.5 x 11, 80g/m
2
paper)
Paper exit paper size/
kind
All kinds of paper which can be fed
Shifter function Yes
Paper remaining
detection for paper exit
Ye s
Copy
magnification
ratio
AB
series
25%, 50%, 70%, 81%, 86%, 100%,
115%, 122%, 141%, 200%, 400%
Inch
series
25%, 50%, 64%, 77%, 100%, 121%,
129%, 200%, 400%
Zoom 25 - 400%
(Restriction by the document feeder unit: 50 - 200%)
Exposure mode Binary: Automatic, Text, Text/Photo, Photo
Number of manual
steps
5 steps
System Switchback system
Paper size A3, B4, A4, A4R, B5, B5R, A5, 11 x 17,
8.5 x 14, 8.5 x 13, 8.5 x 11, 8.5 x 11R
Type and weight of
paper which can be
passed
56 - 105g/m
2
/15 - 21.3 lbs Bond
Duplex print from manual paper feed can be
made. (Except for heavy paper, OHP sheet,
and other special paper)
Automatic paper selection
Automatic magnification ratio selection
Vertical/horizontal independent magnification ratio
Paper type selection
Auto tray switching
Rotation copy
Electronic sort
Job reservation (only during warm-up)
Program call-out/registration (10 items)
Preheat function
Auto power shut off function
User management (100 items)
Mixed documents feed (MIX only)
Binding margin (Left/Right/Upper)
Edge erase/Center erase (Center/Edge/Center + Edge)
1 set 2 copy
Cover paper/Insert paper (Cover/Back cover only)
Multi shot (2 in 1/4 in 1) (Centering available)
Card shot (Centering available)
Pamphlet mode (Centering available)
Duplex copy direction switching
Large volume document mode
Black/white reverse (except for UK)
Stream feeding mode (ON/OFF switch by the system setting)
•IBM PC/AT
•Macintosh
OS SPLC
Windows 2000
Ye sXP
XP x64
Server 2003
No
Server 2003 x64
Vista
Ye s
Vista x64
Server 2008
No
Server 2008 x64
Mac 9.0 - 9.2.2
X 10.2.8
X 10.3.9
X 10.4.11
X 10.5 - 10.5.6
Standard environmental
conditions
Temperature 20 - 25°C
Humidity 65 ± 5%RH
Usage environmental
conditions
Temperature 10 - 35°C
Humidity 20 - 85%RH
Atmospheric
pressure
590 - 1013 hPa
(height: 0 - 2000m)
(Humidity)
85%
60%
20%
10 C 30 C 35 C
(Temperature)