Example
Maximum travel distance s
max
: 60 m
Minimum distance calculation: a ≥ 0.0083 x 60 m = 0.5 m
Dx100-2xxBxxxx
No minimum distance is required for the arrangement of a distance sensor with inte‐
grated spectral filter (Dx100-2xxBxxxx from serial number 1926xxxx) to an ISD400-7xxx
optical data transmission system. The following arrangement is required when doing so:
1
2
4
3
S
e
t
E
s
c
<
<
Figure 11: Arrangement of distance sensor Dx100-2xxBxxxx to data transmission system
ISD400-7xxx
1
Dx100-2xxBxxxx distance sensor
2
Reflector
3
ISD400-7xx2, infrared
4
ISD400-7xx1, red
5.5.2 Assignment to ISD300, ISD400-1xxx or ISD400-6xxx
A minimum distance of at least 100 mm must always be maintained when mounting a
data transmission system of the ISD300, ISD400-1xxx and ISD400-6xxx product family.
The maximum measurement distance and variant of the distance sensor does not have
an impact on the minimum distance.
5 MOUNTING
24
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP 8016994/19HB/2022-03-15 | SICK
Subject to change without notice