7.1.6 MFx On menu
In this menu, you can activate or deactivate multifunctional input/output MF1 and
multifunctional output MF2.
Requirement for display
More? menu: Yes option.
Table 12: MFx On menu
Options Description
Enable / Disable Activate or deactivate MF1 and MF2.
Options
•
Enable: MF1 and MF2 are activated in the hardware.
•
Disable: MF1 and MF2 are deactivated in the hardware and are therefore
hidden in the menu.
Factory setting
•
Enable
7.1.7 MF1 menu
You can parameterize multifunctional input/output MF1 using this menu.
Requirement for display:
•
more? menu: Yes option
•
Menu MFx On: Enable option
Table 13: MF1 menu
Parameter Description
ActSta Select the active level or signal edge of the MF1.
Options
•
ActLow: LOW level output with active output (safety criterion fulfilled) or
activation of input at falling signal edge
•
ActHi: HIGH level output with active output (safety criterion fulfilled) or
activation of input at rising signal edge
Factory setting
•
ActLow
Functn Select MF1 function.
Options
•
Dist: MF1 is used as a distance switch output.
•
Speed: MF1 is used as a speed switch output.
•
Srvice: MF1 is used as a service output.
•
LsrOff: MF1 is used as an input for switching off the laser.
•
Preset: MF1 is used as an input for activating the static preset.
Factory setting
•
Dist
The corresponding menu is displayed depending on the function selected for
the Functn parameter. See the relevant table for the parameter description.
Count Counts the switching events of the MF1. You can reset the counter by
switching the device off and on again.
7.1.8 MF1 – Dist submenu
In this submenu, you can configure the MF1 as a distance switch output.
7 OPERATION
36
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP 8016994/19HB/2022-03-15 | SICK
Subject to change without notice