Table 16: MF1 – Srvice submenu
Parameter Description
WrnLsr Activates MF1 when the aging of the laser diode means that the device is
nearly due to be replaced.
Options
•
On
•
Off
Factory setting
•
On
WrnLvl Activates MF1 when the signal attenuation value reaches the critical value,
for example due to contamination.
Options
•
On
•
Off
Factory setting
•
On
WrnTemp Activates MF1 if the interior device temperature reaches the critical value.
Options
•
On
•
Off
Factory setting
•
On
WrnPlb Activates MF1 if extrapolated measured values are output for implausible
measured values see table 20, page 42, ErrRej. This may be caused by
an internal error, hardware errors, obstruction of the light beam, optical
interference or electrical interference.
Options
•
On
•
Off
Factory setting
•
On
NotRdy Activates MF1 if the device is not ready for operation. Possible causes could
be hardware errors, optical or electrical interference or a deactivated laser
diode. This warning message is also issued during initialization.
Options
•
On
•
Off
Factory setting
•
On
Heat Activates MF1 if the interior device heating is in operation. This parameter is
only displayed on measuring devices with the “Heating” option.
Options
•
On
•
Off
Factory setting
•
Off
7.1.11 MF1 – LsrOff submenu
You can parameterize the MF1 as a switching input to switch off the laser diode by
selecting LsrOff. If MF1 is active, the laser diode is switched off.
OPERATION 7
8016994/19HB/2022-03-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP
39
Subject to change without notice