7 Operation
NOTICE
Device parameterization should not be carried out via the display, but exclusively via
the fieldbus interface with the help of the controller-specific project planning tool, see
"Commissioning in EtherNet/IP network", page 68.
NOTICE
Pushbutton damage due to improper handling!
Improper handling of the pushbuttons can damage them. This will make operation
difficult or impossible.
Only operate the pushbuttons with your fingers or a suitable pointing device.
Do not operate the pushbuttons using sharp or hard objects.
NOTE
For basic instructions for the display and control elements, see "Display and control
elements", page 14. Pressing the pushbutton for more than 2 seconds switches
from measured value display to menu display operating mode.
For the overall menu structure, see "Menu structure", page 83.
NOTE
Parameters set using the operating buttons are not permanently saved until the system
jumps back to the measured value display. Depending on the menu level, it jumps back
if the is pushed several times or automatically if no button is pressed for longer
than 90 seconds. Depending on the changed parameter, the device restarts when
switching to the measured value display, which causes a brief interruption in fieldbus
communication.
7.1 Parameter description
7.1.1 Main menu
The distance value is shown in the display by default. With the pushbutton, you can
switch from the distance value display to the bar graph level display and other process
values.
You can scroll through the process values in the main menu using the and
pushbuttons.
Table 7: Process values
Process values Description
Distance value Display of distance value in mm
Bar graph level Display of the received signal level as a bar graph
Numerical level Display of the received signal attenuation as a numerical value
see "Received signal level", page 28.
Temperature Display of the internal device temperature
Laser operating hours Display of the operating hours of the laser diode
Warnings Displays the pending warnings. If there is a warning pending, the
PWR LED flashes orange. If there are no warnings pending, NoWarn
is displayed, see "Warning messages", page 72.
7 OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP 8016994/19HB/2022-03-15 | SICK
Subject to change without notice