EasyManua.ls Logo

SICK DL100 Pro EtherNet/IP - MF2 Menu; Offset Menu

SICK DL100 Pro EtherNet/IP
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.1.13 MF2 menu
You can parameterize MF2 in this menu and its submenus.
Requirement for display:
more? menu: Yes option
Menu MFx On: Enable option
Table 18: MF2 menu
Parameter Description
ActSta Select active MF2 level.
Options
ActLow: LOW level output with active output (safety criterion fulfilled)
ActHi: HIGH level output with active output (safety criterion fulfilled)
Factory setting
ActLow
Functn Select MF2 function.
Options
Dist: MF2 is used as a distance switch output.
Speed: MF2 is used as a speed switch output.
Srvice: MF2 is used as a service output.
Factory setting
Srvice
Count Counts the switching events of the MF2. You can reset the counter by
switching the device off and on again.
MF2 – Dist submenu
This submenu corresponds to the Dist submenu in the MF1 menu see "MF1 – Dist
submenu", page 36.
MF2 – Speed submenu
This submenu corresponds to the Speed submenu in the MF1 menu see "MF1 – Speed
submenu", page 37.
MF2 – Srvice submenu
This submenu corresponds to the Srvice submenu in the MF1 menu see "MF1 – Srvice
submenu", page 38.
7.1.14 Offset menu
You can set an offset in this menu.
Requirement for display:
more? menu: Yes option
OPERATION 7
8016994/19HB/2022-03-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP
41
Subject to change without notice

Table of Contents

Related product manuals