Process values Description
Error Display of the pending errors. If there is an error pending, the PWR
LED flashes red. If there are no errors pending, NoErr is displayed,
see "Error messages", page 73.
You get from measured value display to menu operation by pressing the pushbut‐
ton. You can use the pushbutton to select between displaying the Menu device
parameter, the SwVers software version and the HwVers hardware version in the main
menu. Select the respective menu and confirm by pressing the pushbutto.
7.1.2 SwVers menu
The SwVers menu displays all information relating to the software.
Table 8: SwVers menu
Parameter Description
App-uC Displays the version of the application processor
FPGA Displays the version of the FPGA (field programmable gate array)
Com-uC Displays the version of the communication processor
NOTE
Since the display can only show a total of 6 characters, this information is automatically
displayed as running text.
7.1.3 HwVers menu
The HwVers menu displays all information relating to the hardware.
Table 9: HwVers menu
Parameter Description
HwVers Display of the version number (=hardware update number). During initial
delivery, this corresponds to the serial number and can change due to a
hardware update during repair.
7.1.4 Menu menu
The Menu menu contains all device parameters.
Table 10: Menu menu
Options Description
more? Activation of advanced menu view see "More? menu", page 35.
7.1.5 More? menu
In the more? menu, you can activate or deactivate the advanced menu view.
Table 11: More? menu
Options Description
Yes / No Activate or deactivate advanced menu view The entire menu is displayed
when activated. When deactivated, the MF1, MF2, Offset and SpecFu parame‐
ters are hidden.
Options
•
Yes
•
No
Factory setting
•
No
OPERATION 7
8016994/19HB/2022-03-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP
35