Table 32: Attribute 47: Warnings
Bit Description FALSE (0) TRUE (1)
0...10 Defined by CIP Always 0 -
11...12 Reserved by CIP Always 0 -
13 Manufacturer specific OK Laser warning
14 Manufacturer specific OK Level warning
15 Manufacturer specific OK Temperature warning
Table 33: Attribute 48: Supported Warnings
Bit Description FALSE (0) TRUE (1)
0...10 Defined by CIP Not supported -
11...12 Reserved by CIP Not supported -
13 Manufacturer specific
Laser warning
- Supported
14 Manufacturer specific
Level warning
- Supported
15 Manufacturer specific
Temperature warning
- Supported
10.7.2 Device-specific instance attributes
Device-specific - process values, status, laser control, preset
These attributes include process values, status information, laser control, and additional preset functions.
Table 34: Instance attributes for process values, status, laser control, preset
Attribute ID Name Description Min. .... Max.
Default
Type Size
[bytes]
Get/Set
100 Level Signal attenuation [dB] see "Received signal
level", page 28
-127...-30
(typ.)
-
Int 2 Get
101 Temperature Internal device temperature in [°C] -128...127
-
SINT 1 Get
102 Operating Hours Laser operating hours [h] 0...4,294,96
7,295
-
UDINT 4 Get
103 Status, warnings
and alarms
Device status and operational status of MFx,
laser and heating see table 35, page 61
- Word 2 Get
104 Laser Control Switch laser off/on
Options:
0: LASER OFF
1: LASER ON
0...1
1
BOOL 1 Set
105 Dynamic preset Dynamic preset via the cyclic output data of
output assembly 128.
see table 36, page 61 or see "Preset –
move to initialization position", page 66
-
0
DINT 4 Set
106 Reset Preset /
Offset
Resetting a previously triggered preset and
setting the offset to value 0 on rising edge
0→1 see "Preset – move to initialization posi‐
tion", page 66
Options:
0: OFF
1: ON
0...1
0
BOOL 1 Set