Attribute ID Name Description Min. ... Max.
Default
Data
type
Size
[bytes]
Access
46 Alarm flag Logical OR over all alarm bits from attribute
44.
Options
0: OK
1: Alarm / Error
0...1
-
BOOL 1 Get
47 Warnings Warning messages see table 32, page 60 - Word 2 Get
48 Supported warn‐
ings
Supported warning messages from attribute
47 see table 33, page 60
-
0xE000
Word 2 Get
49 Warning flag Logical OR over all warning bits from attribute
47.
Options
0: OK
1: Warning
0...1
-
BOOL 1 Get
51 Offset value Offset value [mm] see "Preset – move to initi‐
alization position", page 66
-600,000...3
00,000
0
DINT 4 Get
Table 29: Attribute 41: Operating Status
Bit Description FALSE (0) TRUE (1)
0 Measurement direction (attrib‐
ute 12)
REVERSE FORWARD
1 Resolution distance value
(attribute 15)
0.1 mm All others
2...4 Reserved by CIP Always 0 -
5...7 Manufacturer specific Always 0 -
Table 30: Attribute 44: Alarms
Bit Description FALSE (0) TRUE (1)
0 Position error OK Plausibility error
1 Diagnostic error Always 0 -
2...11 Reserved by CIP Always 0 -
12 Manufacturer specific Always 0 -
13 Manufacturer specific OK Error laser
14 Manufacturer specific OK Level error
15 Manufacturer specific OK Temperature error
Table 31: Attribute 45: Supported Alarms
Bit Description FALSE (0) TRUE (1)
0 Plausibility error - Supported
1 Diagnostic error Not supported -
2...11 Reserved by CIP Not supported -
12 Manufacturer specific Not supported -
13 Manufacturer specific
Error laser
- Supported
14 Manufacturer specific
Level error
- Supported
15 Manufacturer specific
Temperature error
- Supported
ETHERNET/IP INTERFACE 10