13.3 Supply
Table 50: Supply
Supply voltage V
S
18 V DC … 30 V DC, reverse polarity protected
Current consumption (with‐
out load)
Without heating: < 250 mA at 24 V DC
With heating: < 1,000 mA at 24 V DC
Residual ripple < 5 V
SS
within the permissible supply voltage U
V
13.4 Inputs
Table 51: Inputs
Inputs Multifunctional input MF1, switching function adjustable
Switching type: Source for PNP output (open input corresponds to
the LOW input signal)
HIGH > 12 V
LOW < 3 V
Circuit protection None, no reverse-polarity protection.
13.5 Outputs
Table 52: Outputs
Outputs Multifunctional outputs MF1 and MF2, type B (push/pull), adjusta‐
ble switching function
HIGH > U
V
– 3 V
LOW < 2 V
Circuit protection
Short-circuit protected
Overload-proof
Maximum output current Max. 100 mA
Output load
Capacitive: 100 nF
Inductive: 20 mH
13.6 Interfaces
Table 53: Interfaces
2x Ethernet
Process data interface EtherNet/IP
Configuration/Service interface (SOPAS ET)
13.7 Ambient data
Table 54: Ambient data
Protection class
Suitable for operation in PELV (Protective Extra Low Voltage) sys‐
tems with safe separation.
Electromagnetic compati‐
bility
EN 61000-6-2, EN 61000-6-4, Class A
Ambient operating temper‐
ature range
–20 ... +55 °C
2)
–40 ... +55 °C (with integrated heating)
3)
-20 ... +75 °C (with cooler housing TPCC)