EasyManua.ls Logo

SICK DL100 Pro EtherNet/IP - Structural Design

SICK DL100 Pro EtherNet/IP
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warehouse ambient tem‐
perature range
-40 … +75 °C
Relative humidity Max 95% (non-condensing)
Enclosure rating IP 65
Effect of air pressure 0.3 ppm/hPa
Effect of temperature 1 ppm/K
Temperature drift Typically 0.1 mm/K
Maximum traversing speed 15 m/s
Maximum acceleration 15 m/s²
Mechanical strength EN 60068-2-27 (Ea): Continuous shock: 25 g / 6 ms, half sine, 6
axes, 500 shocks per axis
EN 60068-2-27 (Ea): Shock: 30 g / 6 ms, half sine, 6 axes, 3
shocks per axis
EN 60068-2-64 (Fh): Broadband noise vibrations: 10 g rms, 10…
500 Hz, 6 axes, 2 h per axis
1)
The device may cause interference if used in a residential environment.
2)
A warm-up phase until activation of the laser diode is required for temperatures under –10 °C; typical
duration at –20 °C: 20 min at 24 V.
3)
For operation below –20 °C, a supply voltage of at least 24 V is required. A warm-up phase up until
activation of the laser diode is required for temperatures under –10 °C: typical duration at –40 °C:
35 min at 24 V.
4)
Maximum 95% humidity, non condensing
13.8 Structural design
Table 55: Structural design
Dimensions see "Dimensional drawing", page 80
Weight
Device: approx. 800 g
Alignment bracket (optional): approx. 800 g
Materials
Housing: Cast aluminum GD-AlSi12Cu1 (3.2982.05)
Viewing window: PMMA
Connections
M12, SpeedCon™-compatible
Display
6-digit with a 5 x 7 dot matrix
TECHNICAL DATA 13
8016994/19HB/2022-03-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro EtherNet/IP