Table 46: LED Net
LED Net Status Measures
Off
•
No operation
•
No Ethernet connection available
•
No IP address assigned
•
Check the supply voltage
•
Check Ethernet connection
•
Check IP settings
Flashing green
•
Ethernet connection available
and IP address assigned, but no
CIP connection established
•
Check project planning in control‐
ler (at least one Exclusive Owner
connection must be available)
•
Check IP settings
•
Restarting
Flashing red
•
Timeout in Exclusive Owner CIP
connection
•
Check Ethernet connection
•
Establish new CIP connection
•
Restarting
Lit red
•
Duplicate IP address detected
•
Check IP settings
Green/red flash‐
ing (1x)
•
Device self-test
-
Table 47: LED Mod
LED Mod Status Measures
Off
•
No operation
•
Check the supply voltage
Flashing green
•
No Ethernet connection available
•
DEVICE_NOT_CONFIGURED
•
Check Ethernet connection
•
Check project planning in control‐
ler
Flashing red
•
Incorrect or inconsistent configu‐
ration.
•
Check project planning in control‐
ler
Lit red
•
Serious unrecoverable error
•
Contact SICK Service
Green/red flash‐
ing (1x)
•
Device self-test
-
12.6 Returns
b
Only send in devices after consulting with SICK Service.
b
The device must be sent in the original packaging or an equivalent padded pack‐
aging.
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
•
Details of the contact person
•
Description of the application
•
Description of the fault that occurred
12.7 Repairs
Repair work on the device may only be performed by qualified and authorized personnel
from SICK AG. Interruptions or modifications to the device by the customer will invalid‐
ate any warranty claims against SICK AG.