Page #53 background image
Protection class
Circuit protection U
V
connections reverse polarity protected
Output Q short-circuit protected
Output Q overload protected
1)
without load
Mechanical data
Table 24: Mechanical data
Connection type M8, M12
Cable diameter Ø 3.4 mm
Cable cross-section AWG26, 0.14 mm²
Housing material Aluminum and plastic PMMA
Overvoltage protection 1 A
Weight 30 g + 530 g * housing length
Communication interface
Table 25: Communication interface
IO-Link V1.1
Data transmission rate 230.4 mm/s (COM3)
Cycle time 2.3 ms
Process data length 32 Bytes
Process data structure Each byte configurable
Factory setting depending on type code
Maximum length of cable 20 m
Ambient environment
Table 26: Ambient environment
Enclosure rating IP65, IP67
Electromagnetic compatibility EN 61000-6-2
EMC radiated emission EN 61000-6-4
Ambient temperature, operation -25 °C ... +55 °C
Ambient temperature, storage -25 °C ... +70 °C
Ambient light immunity SLGxxx-xxxxAxxxxxx / SLGxxx-xxxxBxxxxxx:
30,000 lx direct sunlight
SLGxxx-xxxxCxxxxxx:
100,000 lx direct sunlight
Vibration resistance Sine wave: 10-150 Hz, 0.35 mm
IEC 60068-2-6
Shock resistance Single shocks: 15 g, 16 ms
Continuous shocks (500 per axis): 10 g,16 ms
DIN EN 60068-2-27
Smart Task
Table 27: Smart Task
Smart Task designation Basic logic
Logic function Direct, AND, OR
TECHNICAL DATA 11
8026014/2021-06-10 | SICK O P E R A T I N G I N S T R U C T I O N S | SLG-2
53
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK SLG-2 and is the answer not in the manual?

SICK SLG-2 Specifications

General IconGeneral
BrandSICK
ModelSLG-2
CategorySwitch
LanguageEnglish

Related product manuals