EasyManua.ls Logo

SICK SLG-2 - Page 53

SICK SLG-2
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protection class
Circuit protection U
V
connections reverse polarity protected
Output Q short-circuit protected
Output Q overload protected
1)
without load
Mechanical data
Table 24: Mechanical data
Connection type M8, M12
Cable diameter Ø 3.4 mm
Cable cross-section AWG26, 0.14 mm²
Housing material Aluminum and plastic PMMA
Overvoltage protection 1 A
Weight 30 g + 530 g * housing length
Communication interface
Table 25: Communication interface
IO-Link V1.1
Data transmission rate 230.4 mm/s (COM3)
Cycle time 2.3 ms
Process data length 32 Bytes
Process data structure Each byte configurable
Factory setting depending on type code
Maximum length of cable 20 m
Ambient environment
Table 26: Ambient environment
Enclosure rating IP65, IP67
Electromagnetic compatibility EN 61000-6-2
EMC radiated emission EN 61000-6-4
Ambient temperature, operation -25 °C ... +55 °C
Ambient temperature, storage -25 °C ... +70 °C
Ambient light immunity SLGxxx-xxxxAxxxxxx / SLGxxx-xxxxBxxxxxx:
30,000 lx direct sunlight
SLGxxx-xxxxCxxxxxx:
100,000 lx direct sunlight
Vibration resistance Sine wave: 10-150 Hz, 0.35 mm
IEC 60068-2-6
Shock resistance Single shocks: 15 g, 16 ms
Continuous shocks (500 per axis): 10 g,16 ms
DIN EN 60068-2-27
Smart Task
Table 27: Smart Task
Smart Task designation Basic logic
Logic function Direct, AND, OR
TECHNICAL DATA 11
8026014/2021-06-10 | SICK O P E R A T I N G I N S T R U C T I O N S | SLG-2
53
Subject to change without notice

Table of Contents

Related product manuals