5 Electrical installation
5.1 Notes on electrical installation
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to the equipment.
Only operate the SLG-2 with safety/protective extra-low voltage (SELV/PELV).
The SLG-2 is a device of protection class III.
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to the equipment.
Only operate the SLG-2 with an LPS (limited power source) in accordance with IEC
60950-1 or an NEC Class 2 power supply unit.
NOTICE
Equipment damage or unpredictable operation due to working with live parts!
Working with live parts may result in unpredictable operation.
Only carry out wiring work when the power is off.
Only connect and disconnect electrical connections when the power is off.
NOTICE
Device damage due to incorrect connection!
Incorrect connection may cause damage to the SLG-2.
The electrical installation must only be performed by electrically qualified person‐
nel.
Standard safety requirements must be observed when working on electrical
systems!
Only switch on the supply voltage for the device when the connection tasks have
been completed and the wiring has been thoroughly checked.
When using extension cables with open ends, ensure that bare wire ends do not
come into contact with each other (risk of short-circuit when supply voltage is
switched on!). Wires must be properly insulated from each other.
Wire cross-sections in the supply cable from the user’s power system must be
selected in accordance with the applicable standards.
Only operate the device with an LPS (limited power source) in accordance with IEC
60950-1 or an NEC Class 2 power supply unit.
All circuits connected to the device must be designed as SELV/PELV circuits.
Operation in short-circuit protected network at max. 8 A.
The IP enclosure rating for the device is only achieved under the following conditions:
The cables plugged into the connections are screwed tight.
If these instructions are not complied with, the IP enclosure rating for the device is not
guaranteed!
ELECTRICAL INSTALLATION 5
8026014/2021-06-10 | SICK O P E R A T I N G I N S T R U C T I O N S | SLG-2
21
Subject to change without notice