Temperature thresholds: Highest / lowest permissible temperature limits can be
set. If the temperature is exceeded or undercut, a warning signal is output
(see "Diagnostics and troubleshooting", page 44).
NOTE
The device temperature is different from the ambient temperature. Since the
temperature is only measured at one point inside the device, other tempera‐
tures may prevail at other points inside the device.
Operating hours diagnostics: Output of the operating hours as well as parameteriza‐
tion option of operating hour limits:
°
Total operating hours: Total operating hours since initial commissioning
°
Operating hours since last reset: Operating hours since last reset
°
Operating hours threshold: Maximum permissible operating hours can be para‐
meterized. If this value is exceeded, a warning signal is output (see "Diagnos‐
tics and troubleshooting", page 44).
Figure 34: Temperature values and temperature limits
7.9.1 Diagnostic settings via IO-Link
Table 9: Diagnostic settings via IO-Link with associated index
IO-Link Index Object name Description
2 System command 130 / Factory
reset
All settings are reset to the fac‐
tory settings.
2 Standard Command 228 / Reset
diagnostic parameter
Resets the measured max/min
temperatures (153) and the
operating hours (190).
153 Current temperature Outputs the current measured
device temperature
153 Maximum temperature all time Outputs the maximum meas‐
ured temperature value
153 Minimum temperature all time Outputs the minimum measured
temperature value
153 Maximum temperature since last
reset
Outputs the maximum meas‐
ured temperature value since
the last reset
153 Minimum temperature since last
reset
Outputs the minimum measured
temperature value since the last
reset
OPERATION 7
8026014/2021-06-10 | SICK O P E R A T I N G I N S T R U C T I O N S | SLG-2
41
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK SLG-2 and is the answer not in the manual?

SICK SLG-2 Specifications

General IconGeneral
BrandSICK
ModelSLG-2
CategorySwitch
LanguageEnglish

Related product manuals