Mounting
18 © SICK AG • Subject to change without notice • 8014865/ZUJ3/2018-11-29
Overallresponsetime Response time
overall
= 4 • [(1.1 ms • n) + 0.75 ms • (1 + 2 + … + n)] +
sum of the response times of all connected sensors
n: Number of connected sensors
Multiplex mode structure and operat-
ing principle
t
PIN 5
Fig. 5: Multiplex mode