EasyManua.ls Logo

SICK UM18-2 Pro - Page 18

SICK UM18-2 Pro
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting
18 © SICK AG • Subject to change without notice • 8014865/ZUJ3/2018-11-29
Overallresponsetime Response time
overall
= 4 • [(1.1 ms • n) + 0.75 ms • (1 + 2 + … + n)] +
sum of the response times of all connected sensors
n: Number of connected sensors
Multiplex mode structure and operat-
ing principle
t
PIN 5
Fig. 5: Multiplex mode

Table of Contents