COMMISSIONING 6
8026364 / V1-0/2022-03|SICK
Subject to change without notice
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
▸
Change the IP address of the configuration PC to the altered address range of the
relevant device.
▸
In the title bar of the device tile, click on the icon with the three dots and select
Remove device entry.
▸
Perform a new device search in SOPAS. The device is found with its new IP address and
displayed in the device list.
▸
Add the device with port 2111 to the SOPAS project.
▸
Connect the second LMS4x21 to a free port on the LFT Ethernet switch.
NOTE! As the default IP address for the first 2D LiDAR sensor was changed, this device
can remain connected via Ethernet.
▸
Perform a device search and change the default IP address as described.
NOTE! It is not necessary to install the device driver for the LMS4x21. This was already
completed when the first 2D LiDAR sensor was added.
▸
Change the IP address of the configuration PC to the address range of the SIM2000-2
Prime controller.
▸
Perform a device search and change the default IP address as described.
The SIM2000-2 Prime controller and 2D LiDAR sensor, along with their device tiles,
are now included in the SOPAS project.
Procedure in the
event of deviating
address ranges
Configuring the
IP address of the
second LMS4x21
Changing the
IP address of the
SIM2000-2 Prime
controller