Product description
Application Module FM 458-1 DP - User Manual 2-11
A5E01078222-02 Edition 03.2009
The PROFIBUS DP interface is connected to the 9-pin sub-D socket.
PIN Designation
1 Not assigned / Ground M24V (non-isolated)
2 Not assigned
3 Line B (input/output)
4 RTS from AS (input)
5 Ground 5Vexternal, floating
6 5Vexternal power supply voltage, floating
7 Not assigned / supply voltage P24V (non-isolated)
8 Line A (input/output)
9 RTS from PG (output)
Enclosure Shield
Table 2-5 Connector assignment of X3
NOTE
Maximal permissible load for 5Vexternal: 90 mA
!
WARNING
There is a potential danger that connectors X1 and X3 are
interchanged (both connectors are sub-D 9 socket connectors).
An expansion module (EXM438-1 or EXM 448/EXM 448-2) can be
inserted at this 5 x 24-pin socket connector.
Two 5 x 17-pin socket connectors are the connectors on SIMATIC S7
backplane bus. K-bus connection
A 5 x 7-pin socket connector is provided to connect to the
SIMATIC K bus.
The terminals for the binary inputs are available via the interface
modules.
Interface modules Function
SB10, SU12 Electrical 1:1 connection, no signal conversion
SB61 With electrical isolation and signal conversion
Refer to Catalog ST DA for information on the interface modules.
NOTE
The operation of the FM 458-1 DP is only allowed with these interface
modules.
The interface modules are “open type” and therefore only can be
installed in closed switch cabinets or switch rooms.
PROFIBUS interface
(X3)
15
69
LE-bus connection
P-bus connection
Interface modules