EasyManua.ls Logo

Siemens 6SR41 series - Table 5- 26 Fifteen Cell Output Filter, Inductance

Siemens 6SR41 series
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Description
5.4 Long Cable Filters
Product User Manual
Operating Instructions, Version AE 12/2009, A5E01454341C
99
Table 5- 26 Fifteen Cell Output Filter, Inductance
Cell Size L, Inductance L % @ 50Hz L % @ 60Hz CT Ratio (# of turns)
40 A 37.90 mH 7.50 9.00 20
70 A 22.00 mH 7.62 9.14 30
100 A 15.90 mH 7.87 9.44 50
140 A 11.00 mH 7.62 9.14 50
200 A 7.00 mH 6.93 8.31 50
260 A 5.80 mH 7..46 8.95 50
Note
Actual project L and C values are subject to change.